60KW burn in system
60KW burn in system
This 60KW high-power aging system is designed for long-term reliability testing of power supply products. Capable of testing 40 positions simultaneously, it utilizes regenerative loads and precise temperature control to verify product stability and endurance under continuous full-load operation.
| Dimension(L*W*H) | 2200+800mm*1600mm*2160mm |
|---|---|
| Oven Capacity | 1500W:40units |
| Applicable Products | Power Supplies and Adapters |
| Input Voltage | 115Vac/230Vac |
Product Features
- Electric leakage protection: Automatically cuts off when leakage is detected
- Over temperature: Automatically cuts off product power and activates alarm
- Smoke detection: Automatically cuts off product power and triggers alarm device
- Fault alarm: Automatically identifies faulty unit and activates alarm
- Emergency shutdown: Used for emergency cut-off of system power
Technical Specifications
Device Parameters
| Parameter | Specification |
|---|---|
| Oven size | 2200+800(L)mmX1600(W)mmX2160(H)mm |
| Input Voltage | 115Vac/230Vac |
| Temperature control range | Room Temp. +10to60°C |
| Temperature stability | ±3°C |
| Alarm system | Trigger by smoke or temperature |
| Oven Capacity | 1500W:40units |
| Datalog signal channel | 40 |
| Datalog function | Remote control & 20ms detection cycle |
| Communication mode | RS485 |
| Regenerative E-load input Voltage (V) | 3-60V |
| Each slot power (W) | 1500 |
| Qty. of test slot | 40 |
| Regenerative E-load total Power (KW) | 60 |
Main Functions
- Constant temperature auto control
- Regenerative electric load
- Input voltage auto select
- Input On/Off cycle auto control
- Loading current auto control
- Output data and signal acquisition
- Alarm signal monitoring and automatically shut down the input power when temperature & voltage monitored is out of limit
- Removable
- PMBus/IIC communication