RF Burn-in System
RF Burn-in System
This system is designed for RF power supply aging tests, simulating high-frequency operating conditions for high-power endurance testing. It supports 8 high-power units operating simultaneously, ensuring long-term reliability under demanding conditions through water cooling and smart communication.
| Dimension(L*W*H) | 2000mmx1000mmx2000mm |
|---|---|
| Input Voltage | 115Vac1phase/280Vac3phase |
| Applicable Products | RF (Radio Frequency) |
| Temperaturecontro lrange | Water-cooling |
Product Features
- Electric leakage protection: Automatically cuts off when leakage is detected
- Over temperature: Automatically cuts off product power and activates alarm
- Smoke detection: Automatically cuts off product power and triggers alarm device
- Fault alarm: Automatically identifies faulty unit and activates alarm
- Emergency shutdown: Used for emergency cut-off of system power
Technical Specifications
Device Parameters
| Parameter | Specification |
|---|---|
| Dimension | 2000(L)mmX1000(W)mmX2000(H)mm |
| InputVoltage | 115Vac1phase/280Vac3phase |
| Temperaturecontrolrange | Watercolling |
| Alarmsystem | Triggerbysmokeortemperature |
| OvenCapacity | 15000W(8units) |
| Datalogsignalchannel | 384 |
| Datalogfunction | PMBusreading |
| Communicationmode | RS485 |
| Eachslotpower(W) | 15000 |
| Qty.oftestslot | 8 |
| RegenerativeE-loadtotalPower(KW) | 120 |
Main Functions
- Cooling water auto control
- Input voltage auto select
- Input On/Off cycle auto control
- Alarm signal monitoring and automatically shut down the input power when temperature & voltage monitored is out of limit
- Removable
- PMBus