High-power power supply multi-temperature zone B/I system
High-power power supply multi-temperature zone B/I system
This equipment is used for long-term reliability testing of high-power supplies, simulating different temperature environments for continuous aging of power products. The system can simultaneously test 36 high-power units across four independent temperature zones, verifying their stability and endurance under various working conditions.
| Dimension(L*W*H) | 2400+1000mm*1600mm*2160mm |
|---|---|
| Power capacity | 72KW |
| Applicable Products | High-Power Power Supply |
| B/I product QTY | 36slots |
Product Features
- Electric leakage protection: Automatically cuts off when leakage is detected
- Over temperature: Automatically cuts off product power and activates alarm
- Smoke detection: Automatically cuts off product power and triggers alarm device
- Fault alarm: Automatically identifies faulty unit and activates alarm
- Emergency shutdown: Used for emergency cut-off of system power
High-Power Power Supply Burn-In System with Multiple Temperature Zones
General Specifications
| Parameter | Specification |
|---|---|
| Applicable Products | Server and communication power supplies |
| Overall Dimensions (L × W × H) | (2,400 + 1,000) × 1,600 × 2,160 mm |
| Rated Power per Product | 500 W |
| Product Capacity | 36 units |
| Product Operating Voltage | 110/220 V AC |
| Load Type | Energy-saving load |
| Load Modes | Constant Current (CC) / Constant Voltage (CV) |
| Energy Efficiency | 80% at rated power |
| Electrical Control | 24 independent sets |
| System Input Voltage | 220/110 V AC |
| Total Slots | 96 slots, with a 50% on/off duty cycle |
| Power per Slot | 1,500 W |
| Terminals per Slot | 3 |
| Terminal Rating | 500 W; 3–60 V; 50 A max. |
| Total Power Capacity | 72 kW |
Temperature Control
| Parameter | Specification |
|---|---|
| Burn-In Temperature Range | Adjustable from +10°C to approximately 70°C |
| Temperature Zones | 4 |
| Loading Area Temperature | ≤45°C |
| Temperature Control Hardware | PLC, temperature module, and sensor |
Safety and Protection
| Function | Description |
|---|---|
| Electrical Leakage Protection | Automatically shuts off power when electrical leakage is detected |
| Overtemperature Protection | Automatically shuts off product power and activates an alarm |
| Smoke Detection | Automatically shuts off product power and activates an alarm |
| Fault Alarm | Automatically identifies faulty units and activates alarms |
| Emergency Shutdown | Shuts off system power in an emergency |