Automatic Motor Driver Burn-in Line
This equipment is a specialized aging test system for new energy vehicle motor drivers, verifying product reliability by simulating long-term operating conditions. It can simultaneously conduct continuous aging tests on multiple high-power drivers, ensuring their stability and durability in demanding environments.
| Dimension(L*W*H) | 14600*5950*2750(mm) |
|---|---|
| Production Capacity | ≥30PCS/H |
| Applicable Products | Motor Driver for New Energy Vehicles |
| Operator | 2 people |
Product Features
Double speed chain mode
automatic cycle, simple structure, easy maintenance, reliable action, speed can be segmented control, error control;
Line control
reserved segment control, according to the testing requirements of each process; can also carry pallets to make automatic circulation transport;
Modular design
modular design, flexible combination, easy to disassemble and transpose;
Safety protection
high level of safety protection, intelligent stop and power off for safe production;
Technical Specifications
Device Parameters
| Parameter | Specification |
|---|---|
| Description | New Energy Motor Driver Auto Burn-in Line |
| Dimension | 14600(L)*5950(W)*2750(H)mm |
| Production Capacity | ≥30PCS/H |
| Operator | 2 people |
| Output Power of product | Single/Double sets of 80~210KW |
| Operation Voltage of product | 150~1000Vdc max 30KW |
| Auxiliary Voltage | 8~30Vdc max 10A |
| Refrigerant flow | 5~15/20L/Min (programming adjustable) |
| Refrigerant temperature | Room Temp.+5°C~85°C (programming adjustable) |
| Auto-docking Terminal | Staubli/TST/Langan (Customized Services) |
| Rotary Transformer/Temperature simulation | Yingshuang/Standard Resistor |
| Testing, B/I & Loading | Simulated Motor/Non-standard Customized Reactor |
| Testing & Monitoring | Output Voltage, current, power, temperature and communication etc. |
| Reporting | Storage temperature, refrigerant temperature & flow rate, pressure, AC voltage & current etc. |
| MES function | Test data can be uploaded to customer’ s MES system |
Process Procedure
- Non-defective Product Sorting (with NG Product Sorting Capability)
- Manual Screw Removal, Cable Disconnection & Connector Disassembly
- Model Changeover Station
- Manual Screw Fastening, Cable Insertion, Water Connector Plug-in, Scanning & ID Binding
- Steering Buffering Station
- Burn-in Chamber Material Pick-up Waiting Station
- RGV Manipulator Handling & Loading
- Pre-Burn-in Electrical Connection
- Pre-Burn-in Air Tightness Test
- Burn-in Test
- Product Draining
- RGV Manipulator Handling & Unloading
- Reserved Drying Station (Water Removal)
- Temperature-Controlled Cooling Chamber (Air Cooling)
- Room Temperature Cooling Zone
- Return to (Non-defective Product Sorting)


.png)