Communication power supply B/I system
Communication power supply B/I system
This system is designed for server and communication power supplies, performing long-term operation tests by simulating high-temperature environments. It can simultaneously age 36 high-power units, verifying their stability and durability under demanding conditions through precise temperature control.
| Dimension(L*W*H) | 2400+1000mm*1600mm*2160mm |
|---|---|
| B/I slot | 36PCS |
| Applicable Products | Server Power Supply and Telecom Power Supply |
| B/I power per slot | 3KW |
Product Features
- Electric leakage protection: Automatically cuts off when leakage is detected
- Over temperature: Automatically cuts off product power and activates alarm
- Smoke detection: Automatically cuts off product power and triggers alarm device
- Fault alarm: Automatically identifies faulty unit and activates alarm
- Emergency shutdown: Used for emergency cut-off of system power
Technical Specifications
Basic Parameters
| Parameter | Specification |
|---|---|
| Applicable Products | Server / Communication power supply |
| Dimension | 2400+1000(L)*1600(W)*2160(H)mm |
| B/I product power | 3KW |
| B/I slot | 36 slots |
| Product input voltage rang | AC110V/220V |
| Type of Load | Energy saving load |
| Loading mode | CC,CV |
| Energy efficiency | 80% (Rated power) |
Temperature
| Parameter | Specification |
|---|---|
| Range | +10 to ~70°C adjustable |
| Loading area temperature | ≤50°C。 |
| Temperature control hardware | PLC + temperature module + sensor |
| Accuracy | +/- 3°C |
| Uniformity | +/- 3°C |
| Heating rate | 2 °C/min |
| Cooling decreasing rate | 3 °C/min |
Safety
| Parameter | Specification |
|---|---|
| Material | flame retardant material |
| Fire | Smoke detectors |
| Temperature | Overtemperature limit |
| Indicator | Tri-colour light |
Configuration
| Parameter | Specification |
|---|---|
| Total power of equipment | 108KW |
Signal Per Slot
| Parameter | Specification |
|---|---|
| Charger_Enable(to GND) | 2CH |
| Sleep(to GND) | 2CH |
| Data Acquisition | 12CH |
| Enable (12V) | 2CH |
| Ps-On | 2CH |
| PM bus | 2CH |